Description
The OX847 Oxygen Sensor is listed for the Jaguar XJ 5.0 Supercharged V8 Portfolio SWB, X351 series, covering model years 2010–2014. The supplied vehicle details specify a four-door sedan equipped with a 5.0-litre V8 engine featuring 32 valves. This application represents a high-performance luxury vehicle that relies on accurate engine management and exhaust monitoring to support its intended operation.
An oxygen sensor is an important component of the engine management and emissions control systems. It measures the oxygen content in the exhaust gases and sends information to the engine control unit (ECU). The ECU uses this information, together with readings from other engine sensors, to help manage the air-fuel mixture and monitor emissions-related performance.
When an oxygen sensor becomes worn, contaminated or electrically faulty, it may provide inaccurate readings or respond more slowly than expected. If diagnosis confirms that the sensor is defective, replacing it with a correctly matched unit may help restore appropriate feedback to the engine management system.
The OX847 listing provides a replacement option for the specified Jaguar XJ application. However, exact compatibility must be verified before purchase because the 5.0-litre supercharged V8 may use different sensors depending on exhaust position, production specification and original equipment configuration.
Product Specifications
- Product Name: Oxygen Sensor
- Product Code: OX847
- Vehicle Make: Jaguar
- Vehicle Model: XJ 5.0 Supercharged V8 Portfolio SWB
- Model Series: X351
- Model Years: 2010–2014
- Body Style: Four-door sedan
- Engine Capacity: 5.0 litre
- Engine Configuration: V8
- Valve Configuration: 32-valve
- Engine Type: Supercharged petrol V8, as specified in the listing
- Product Function: Exhaust oxygen monitoring and engine management feedback
- Sensor Position: Confirm the required upstream or downstream location
- Connector and Wiring: Must match the original sensor
- Fitment Verification: Confirm VIN, engine code and original equipment part number
These specifications reflect the supplied product title. Buyers should confirm the exact application against their vehicle before ordering.
What Does an Oxygen Sensor Do?
An oxygen sensor, also known as a lambda sensor, measures the amount of oxygen remaining in the exhaust gases after combustion. The ECU interprets its signal to help determine whether the engine is operating with the appropriate air-fuel mixture.
On a compatible petrol-powered Jaguar XJ, oxygen sensor feedback supports fuel control, engine management and emissions monitoring. Accurate information helps the ECU make suitable adjustments under different driving conditions, including idling, acceleration and steady-speed cruising.
Depending on the exhaust system design, a vehicle may have several oxygen sensors. An upstream sensor is generally positioned before a catalytic converter and provides feedback used for fuel mixture control. A downstream sensor is generally positioned after the catalytic converter and helps monitor catalytic converter efficiency.
These sensors may differ in their electrical characteristics, heating elements, connectors and intended functions. On a V8 engine with multiple exhaust banks, the location of the sensor is particularly important. A replacement must match the required bank and sensor position rather than simply fitting the general vehicle description.
Key Features and Benefits
- Exhaust Oxygen Monitoring: Provides information about oxygen levels in the exhaust stream to support engine management.
- Air-Fuel Mixture Feedback: Helps the ECU adjust fuel delivery when the sensor is correctly specified and operating properly.
- Emissions System Support: Assists the vehicle’s exhaust monitoring system in performing its intended function.
- Replacement for a Faulty Sensor: Offers a replacement option when diagnostic testing confirms that the original oxygen sensor has failed.
- Jaguar XJ Application Listing: Specified for the X351 5.0 Supercharged V8 Portfolio SWB from 2010 to 2014, subject to exact fitment verification.
- Potential Diagnostic Improvement: Replacing a confirmed faulty sensor may resolve related warning lights or diagnostic trouble codes when the sensor is the underlying cause.
- Maintenance Support: Helps owners maintain the engine management and exhaust monitoring systems of their vehicle.
The results of replacement depend on correct part selection and the vehicle’s condition. An oxygen sensor cannot correct unrelated mechanical, electrical, fuel delivery or exhaust system faults.
Common Symptoms of a Faulty Oxygen Sensor
A malfunctioning oxygen sensor may cause or contribute to several symptoms. Similar problems can arise from other faults, so diagnosis is recommended before replacing the component.
Common signs include:
- Check Engine Warning Light: The ECU may detect an abnormal sensor signal, heater circuit problem or response issue.
- Increased Fuel Consumption: Incorrect sensor feedback may affect air-fuel mixture control and contribute to higher fuel use.
- Rough Idling: Unreliable sensor readings may contribute to inconsistent engine operation.
- Hesitation or Reduced Responsiveness: An engine management fault may affect driving response under some conditions.
- Increased Exhaust Emissions: Incorrect fuel mixture control or a related engine fault may increase emissions.
- Failed Emissions Testing: A sensor or related emissions system problem may affect inspection results.
- Diagnostic Trouble Codes: A scan tool may identify faults associated with oxygen sensor signals, heater circuits or emissions monitoring.
These symptoms do not automatically confirm that the oxygen sensor has failed. Exhaust leaks, ignition faults, fuel pressure problems, damaged wiring, intake leaks and catalytic converter issues can produce similar warning signs.
Why Correct Fitment Matters
The Jaguar XJ X351 5.0 Supercharged V8 uses a specific engine and exhaust configuration. Oxygen sensors that look similar may have different connector designs, wire lengths, thread dimensions, response characteristics or electrical specifications.
Before purchasing the OX847, verify the following:
- The vehicle’s VIN and engine code.
- The exact model year and Portfolio SWB specification.
- The original equipment oxygen sensor part number.
- The sensor’s location, including exhaust bank and upstream or downstream position.
- The electrical connector and number of wires.
- The thread dimensions and mounting arrangement.
- Any relevant production-date or emissions specification differences.
Because the V8 engine may have multiple sensors, do not assume that one sensor is suitable for every position. Confirm the precise replacement location using the vehicle’s service information or a trusted parts catalogue.
Installation and Maintenance Recommendations
- Diagnose the Fault First: Scan the vehicle for diagnostic trouble codes and inspect sensor readings where possible. Determine whether the sensor itself is defective.
- Allow the Exhaust to Cool: Exhaust components can become extremely hot. Ensure the vehicle is securely supported and the components have cooled before beginning work.
- Compare the Replacement: Check the part number, connector, wiring length, thread and physical design against the original sensor.
- Identify the Correct Position: Confirm the required exhaust bank and whether the sensor is upstream or downstream of the catalytic converter.
- Use Suitable Tools: Use the appropriate oxygen sensor socket or tool to reduce the risk of damaging the sensor or surrounding components.
- Follow Manufacturer Specifications: Observe the specified installation procedure and tightening torque. Use anti-seize compound only if permitted by the sensor manufacturer’s instructions.
- Protect the Wiring: Route the cable correctly and keep it away from hot exhaust surfaces and moving components.
- Check System Operation: Clear codes when appropriate, complete any required drive cycle and recheck the system for returning faults.
- Inspect Related Components: Check for exhaust leaks, wiring damage and other engine problems that may have caused the original sensor issue.
Professional installation is recommended if access is difficult or the correct sensor location is uncertain.
Fitment Checklist
Before ordering OX847, confirm that your vehicle matches the supplied listing:
- Jaguar XJ 5.0 Supercharged V8 Portfolio SWB.
- X351 series.
- Model year 2010, 2011, 2012, 2013 or 2014.
- Four-door sedan.
- 5.0-litre V8 32-valve petrol engine.
- Matching VIN, engine code and original part number.
- Correct exhaust bank and sensor position.
- Compatible connector, wiring and emissions specification.
Conclusion
The OX847 Oxygen Sensor is listed for the 2010–2014 Jaguar XJ 5.0 Supercharged V8 Portfolio SWB X351. This component plays an important role in exhaust oxygen monitoring and provides feedback used by the engine management system to regulate fuel delivery and support emissions control.
When the original sensor has been confirmed faulty, a correctly matched replacement may help restore suitable feedback and resolve related engine management issues. Before purchasing, verify the VIN, engine code, original equipment part number, exhaust bank and sensor position to ensure the selected part is appropriate for your specific Jaguar XJ.






Reviews