Description
Maintain the engine management and emissions monitoring performance of your Toyota Estima with the OX758 Oxygen Sensor. This product listing is intended for Toyota Estima ACR30 and ACR40 models from 2000 to 2006 equipped with the 2.4-litre, four-cylinder, 16-valve petrol engine. The oxygen sensor is an important part of the vehicle’s exhaust monitoring system, supplying information that helps the engine control module (ECM) manage combustion and monitor emissions.
An oxygen sensor, commonly called an O2 sensor or lambda sensor, measures the oxygen content in exhaust gases and sends an electrical signal to the vehicle’s engine management system. The ECM uses this information as part of its fuel-control strategy, helping maintain the intended air-fuel mixture and monitor the operation of emissions-control components.
Over time, an oxygen sensor can become contaminated, deteriorate, or develop an electrical fault. When this happens, the vehicle may store diagnostic trouble codes, illuminate the check-engine warning light, or experience changes in fuel consumption and engine operation. Replacing a sensor that has been correctly diagnosed as faulty may help restore the intended function of the engine management system.
The Toyota Estima 2.4-litre ACR30 and ACR40 commonly use the 2AZ-FE engine. However, the correct replacement depends on the vehicle’s production date, sensor position, and original part specification. Oxygen sensor catalogues identify different applications and sensor configurations across the model years, making fitment verification important before ordering.
Vehicle Compatibility
This listing is intended for the following application:
- Product: Oxygen Sensor
- Product Code: OX758
- Make: Toyota
- Model: Estima
- Chassis Series: ACR30–ACR40
- Model Years: 2000–2006
- Body Style: 4-door, as specified
- Engine Capacity: 2.4 litres
- Engine Configuration: Inline 4-cylinder (I4)
- Valve Configuration: 16-valve
- Engine Code: 2AZ-FE — confirm against the vehicle
- Component: Exhaust oxygen sensor
The ACR30-ACR30W and ACR40-ACR40W 2.4-litre applications are listed in automotive parts catalogues for the 2000–2006 period. Nevertheless, the same model range may use different sensor specifications depending on production date and installation position. Confirm compatibility using the VIN and original sensor part number before purchasing.
What Does an Oxygen Sensor Do?
The oxygen sensor monitors oxygen levels in the exhaust gases. Its readings help the ECM assess combustion and make appropriate fuel-control adjustments when the sensor is used for air-fuel regulation. Oxygen sensor information also supports emissions monitoring and diagnostic functions.
Depending on the exhaust layout, a vehicle may have an upstream sensor before the catalytic converter and a downstream sensor after it. The upstream sensor generally contributes to fuel-control feedback, while the downstream sensor usually helps the ECM monitor catalytic converter performance. These sensors may differ in electrical characteristics, connector design, cable length, and intended function.
For this reason, the OX758 must be matched to the exact position required on the Toyota Estima. Do not assume that a sensor listed for the ACR30 or ACR40 will fit every sensor location or every production version. Correct identification helps avoid installation problems and unresolved engine-management faults.
Key Product Benefits
Supports engine management operation
A correctly specified oxygen sensor supplies information used by the ECM to manage engine operation. If the original sensor has failed, replacing it with a suitable component may help restore the intended sensor feedback.
Helps maintain emissions monitoring
Oxygen sensor readings are part of the vehicle’s emissions-control strategy. A properly functioning replacement helps the system receive the information it needs to monitor exhaust conditions.
May help resolve sensor-related warning lights
A failed sensor or associated circuit can trigger the check-engine light. When diagnosis confirms the sensor is responsible, installing the correct replacement may help resolve the related fault.
Application-focused replacement
The OX758 listing identifies the Toyota Estima ACR30–ACR40 2.4-litre I4 16-valve models from 2000 to 2006. Verifying the chassis series, engine code, and production date helps ensure that the replacement matches the intended vehicle.
Supports ongoing vehicle maintenance
Oxygen sensors operate in a high-temperature environment and can deteriorate through age, contamination, and prolonged use. Replacing a confirmed faulty sensor can form part of an appropriate repair to the engine management and emissions systems.
Common Symptoms of a Faulty Oxygen Sensor
A deteriorating oxygen sensor may contribute to several symptoms, including:
- Check-engine warning light: The ECM may record a sensor signal, heater circuit, or emissions-related diagnostic code.
- Increased fuel consumption: Incorrect feedback may affect fuel-trim adjustments.
- Rough or inconsistent engine operation: A sensor-related fuel-control problem may affect how the engine runs.
- Unusual exhaust emissions: Faulty sensor readings or associated engine problems may affect emissions performance.
- Failed emissions inspection: An unresolved sensor or catalytic converter monitoring fault may contribute to a failed test.
- Stored diagnostic trouble codes: A diagnostic scan may help identify a fault in the sensor or its circuit.
These symptoms can also result from other problems, such as damaged wiring, exhaust leaks, intake leaks, ignition faults, fuel delivery issues, or a deteriorating catalytic converter. A diagnostic scan and appropriate testing should be completed before replacing the sensor.
Installation Guidelines
Allow the engine and exhaust system to cool fully before beginning installation. The original sensor should be removed using the correct tool to avoid damaging the sensor housing, exhaust threads, or surrounding components.
Before fitting the OX758, compare the replacement with the original part. Check the connector, wire count, harness length, thread, and overall configuration. Verify the intended upstream or downstream position and confirm that the replacement is compatible with the vehicle’s VIN and original part number.
Install the sensor in the specified location and tighten it to the manufacturer’s recommended torque. Avoid contaminating the sensing element with oil, grease, or cleaning chemicals. Route the wiring away from hot exhaust parts and moving components, then reconnect the electrical plug securely.
After installation, clear diagnostic codes if appropriate and check whether the original fault returns. A suitable scan tool can be used to review sensor readings and related engine-management data. If a warning light remains on, further diagnosis may be required.
Important Fitment Checklist
Before ordering the OX758, confirm the following:
- Toyota Estima ACR30 or ACR40 chassis series.
- 2.4-litre 2AZ-FE four-cylinder, 16-valve petrol engine, if applicable.
- Vehicle production date within the intended model range.
- Correct upstream or downstream sensor position.
- Matching electrical connector, wire configuration, thread, and cable length.
- Compatibility with the VIN and original equipment part number.
Conclusion
The OX758 Oxygen Sensor is listed for the Toyota Estima ACR30–ACR40 from 2000 to 2006 with the 2.4-litre inline four-cylinder, 16-valve engine. This component plays an important role in exhaust oxygen monitoring and engine management, providing information used by the ECM for fuel-control and emissions-related functions.
For the best fit, verify the engine code, production date, sensor position, and original part number before purchase. Since sensor specifications can vary across the Estima’s production years, confirming the exact application is essential. When the original sensor has been diagnosed as faulty, a correctly matched replacement can help restore the intended operation of the vehicle’s emissions monitoring system.






Reviews
There are no reviews yet.